Welcome to the Swedish NMR Centre (SNC)

User fees at SNC Gothenburg

 


How to acknowledge the Swedish NMR Centre Gothenburg in publications

The Swedish NMR centre at the University of Gothenburg is acknowledged for support.

Description of systems for publications:

600#2 (violet):

600 MHz Oxford magnet equipped with Bruker NEO console and 5mm QCIP 1H/19F/31P/13C/15N cold probe.

700 (green)

700 MHz Bruker magnet equipped with Avance III console and 5mm QCIF 1H/19F/13C/15N cold probe.

800#2 (red)

800 MHz Oxford magnet equipped with Bruker Avance HDIII console and 5mm TXO 13C/1H/15N cold probe.

800#1 (indigo)

800 MHz Oxford magnet equipped with Bruker Avance HDIII console and 3mm TCI 1H/13C/15N cold probe.

900 (blue)

900 MHz Oxford magnet equipped with Bruker Avance HDIII console and 3mm TCI 1H/13C/15N cold probe.


Booking overview at SNC Gothenburg

Booking of instruments at the NMR Centre is done by the staff. If you want to request time on a magnet, use the relevant access form on this page. If you have any questions regarding booking, e-mail Cecilia Persson.

The booking situation of the instruments can be examined by clicking here. 

 

 

600#2 Walkup

The 600#2 1H/19F/31P/13C/15N CryoProbe is available for Walkup use. We will routinely fill nitrogen and helium and at these occasions pause the queue for 1-3 hours.

To get access email snc@nmr.gu.se.

Documents for access (below):

  1. Check list

  2. Rack positions for each PI group / user.

  3. Introduction to walkup.

 

Current operating mode 600 ‘white’

METABOLOMICS

Planned date for switching operating mode: n/a DIFFUSION

NB! Due to a substantial queue of samples for metabolomics acquisition, probe change to diffusion, imaging or BBO will be planned so that multiple requests can be catered for in sequence. In other words, no switching to non-IVDr-mode for a day or two only. Getting back to IVDr specs after such a switch is a multi-day thing…ergo a wish to minimize switches.




Signal-to-noise characteristics at SNC Gothenburg



900

900

800#2

800#1

700

600#2

600B

400

signal-to-noise in probe installation experiments

3 mm

TCI

5mm

TCI

5mm

TXO

3mm

TCI

5 mm

QCI-F

5 mm

QCI-P

IVDr

diffusion

BBO/BBI

DNP

13C ASTM standard

40% dioxane in benzene-d6

800

1800

3600

600

1200

1200





sucrose standard

2 mM sucrose, 0.5 mM DSS, 2 mM NaN3 in 90:10 H2O:D2O

800

1600

500

800

800

900

400 (IVDr)



15N standard

90% formamid in DMSO-d6

 

 

130

 

30

 

 

 

19F standard

0.05% Trifluorotoluene in chloroform-d









4000

4900





31P standard

0.0485 M triphenyl phosphate (TPP, [C6H5]3PO4) in acetone-d6











600










 


How to acknowledge the Swedish NMR Centre Umeå in publications

The Swedish NMR centre at Umeå University is acknowledged for support.